LD2022

RECESSED SENSOR-SWITCH

FOR 12/24V LED LIGHTING

INSTRUCTIONS & TROUBLESHOOTING

INSTALLATION
1. Connections
Power-in: 12/24VDC, red trace(+)
Power-out to LED light: 5A max., red trace (+)
Maximum load: 60W @ 12V, 120W @ 24V
Sensor-Switches can be connected in parallel.

2. Position magnet along path of arrow. Full test recommended prior to installing.

LD2022 Sensor-Switch direction of magnet

3. Installation with cylindrical magnet
Magnet dimensions: D9.5mm x L30mm
Top of magnet should be level with bottom of sensor-switch for maximum sensitivity.

4. Installation with cuboid magnet
Magnet dimensions: L28mm x W15mm x H6mm
Magnet to be as high as possible for maximum sensitivity.

5. Installation with dome magnet
Magnet dimensions: D16mm x H6.5mm
Magnet to be as high as possible for maximum sensitivity.

TROUBLE SHOOTING

  • Is the supplied magnet within the correct range of the sensor-switch?
  • Is the magnet directly inline with the sensor-switch as indicated by the arrows in 2. above?
  • Is the polarity reversed? Connect LED light directly to the power to ensure power and LED light connections are correct.
  • Check with a spare magnet in all directions.
  • Has the output been short-circuited? A short-circuit on the output may cause unit failure.
  • Contact Lightdream Technical Support for further assistance.

…..